
c Read: Arming Status,AC Power Status, Lists of Faulted Zones, Bypassed
Zones, Zones Currently in Alarm, Zones Currently in Trouble, and RF
sensorswith Low Battery Conditions.
Notes: After the control and the PC have established valid communication, each
keypad on the system will become inactive and will display “CC” or
“MODEM COMM.”. The control,however,will still be scannin
g its zonesand
looking for alarms. If an alarm doesoccur,after communicationis broken off
alarms are sounded and the proper dialer reports are sent to the central
station.The keypadswill becomeactiveafter the downloadcommunicationis
terminated. The detailed operation of the download functions is coveredin
the installation instructions for the V-LINK@ Downloading Software
Diskette.
Remote Prog
.
w Advisory Notes
●
●
●
●
Alarm and trouble reporting may be delayed during the time that the
system and the Downloader are linked to each other following a valid
exchangeof codes,but the proper messagewill get through to the Central
Stationafter the link is broken.
Keypadentriesare ignoredduring the time interval statedabove.
A copy of the program downloaded may be produced from the IBM PC
compatiblecomputer,using the product’sinternal report generator, when
an optional printer is connected(consult your PC manual for proper
printer and connections).
Program Upload or Download Time-Approximately one minute fifteen
secondsfor a completeprogram.
-97-
Comentarios a estos manuales