3,
4.
If the number of digits that you need to enb- in a data field is less than
the maximum digits available (for example,the phone number field), enter
the desired data, then press * and the next data field number to be
programmed.
If you try to enter a non-existent field, the keypad will display EE or
Entry -r. Simply m-enter [*] plus a velid field number. - -
Rewiewinga Data FieWErdng an Entrprna Data Field
Press [#]
plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [*] plus Field No. + [*]. (Applies only to
fields *40-*46, end X4).
Interactive
Mode Programming
(x56, *SO, X81, X2 and x83)
~ical promptdisplayed
Press [*] plus interactive mode No. (for example,*56). The Alpha keypad
during interactivemode
will display the first of a seriesof prompts requestingentries.
progr
Smming
A detailed procedure(with displaysof prompts)is provided in those sections
a
:l::veMode
gramming in the interactivemode is to be performed.
Used To Program
tine Number~
*56 Zone Rogramming
Zone characteristics, report codes, alpha
descriptorsand serial numbers
*8O Relay Programming 4229 or 4204 Relay modules, or Powerline
Carrier devices
*81 Zone List Rogrammiwz ZoneLists for relasdpowerlinecarrier activation
*82 Alpha pro~~
Zone alpha descriptors
*83 Serial No. Add/Delete
5800 seriesTransmitterserial numbers
Loading
Factory Defaults
To load the factory defaults, enter the progr
amming mode, press *7, then
exit the progmmming mode.
*6 resets the Subscriber Account number and CSID in preparation for an
initial download.
spetem
setup Fields
The following program fields must he programmed before doing any zone
Pro~”
*22
*25
*3O
RF SYSTEM
c1
Enter 1 if 588U5882 RF receiveris being use~ enter O if no receiveris
being used. Default is O (none).
WIRED
ZONE EXPANSION
❑
Use this fieldto selectthe type of expansionunit being used, as follows:
O= non% 1 = 4219; 2 = 4229; 3 = 4204. Default is O.
KEYSWITCH ENABLE
❑
This field must be enabled (enter 1) ifusing a keyswitch.The keyswitch
must be connectedto zone 7, which can then not be used for any other
purpose. Default is O (no keyswitch).
Note: Ifkeyswitch is enable~ in menu mode*56 the Zone me (ZT) for
zone 7 wiJlshow“77”, end will not be accessiblefor programming.
*~-
● g Mode
- allows
re-entzyinto the program modeusing Installer Code+ 8 0 0.
W8
inhibits re-entry into the programming modeusing the Installer code.
-2’1-