See TO PROGRAM SYSTEM STATUS AND RESTORE REPORT CODES explanation on
previous pagefor fields *66-*76, and *89.
Press -
Press *7
Press MM
Press *7O
Press *71
Ress *72
Press *73
Press *74
Press *75
-S *76
Press *S9
Press @O
o=
Part>n1
Part’n 2
ARM AWAY/STAY REPORT CODE
0 no
AWAYWAY AWAYW’AY
This option allows for independent programming of AWAY and
STAY reports for eachpartition. 2nd digit of Reportis User No., if
expandedor 4+2 reporting is selected.
RF XMTRwLOW BA’ITERY REPORT CODE
o
I
This
is sent in the event that a wireless lmusmitter low battery
conditionexists.
CANCEL REPORT CODE
o
I
This is sent upon disarming of the system after an alarm
conditionwas reported.
A1.ARM RESTORE REPORT CODE, 1st DIGIT
n
This is sentwhen the zonethat causedan alarm is restoredto its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field *56, if
expandedor 4+2 reporting is selected.
TROUBLE RESTORE REPORT CODE
n
I
This is sent when a trouble in a zone is restored.
BYPASS RESTORE REPORT CODE
m
I
This is sentwhen a zonethat has been bypassedis un-bypassed.
AC RESTORE REPORT CODE
n
I
This is sent when AC powerhas been restored after an AC power
outage. Reportswith Partition 1 Subscriber No.
LOW BAT RESTORE REPORT CODE
n
I
This
is sent when a system low battery condition is restored to
normal.
RF XMTR.
LOW BA’IY’ERY RESTORE CODE
n
I
This is
sent when a transmitter that previously sent in a low
battery messagehas sent a messageindicating it no longer has a
low battqy condition.
TEST RESTORE REPORT CODE
m
This is sentwhen the testmodeis exited. Reportswith Partition
1 SubscriberNo.
EVENT LOG 8(MoFULL REPORT CODE
n
I
If an Event Logging selectionis made in field *O, a messagecan
be sentto the centralstationreceiverwhen the logis 80% fid.1.
Notcx Aside horn the selectionmade by the installerin field *O,
all logcontroland readout is accomplishedvia the Downloader.
EVENT LOGGING
None 1 = Alarm/Alarm Restore 2 = Trouble/Trouble Restore
4 = Byp~s/Bypass Restore;8 = Open/Close. Default is “3”.
ExczmpZe:To select“Alarm/Alarm Restore”,and “Open/Close”,enter 9
(1+ 8); to selectall, enter #15.
Note: Systemmessagesare loggedwhen non-zero selectionsare made.
SeeFields W9 and SO in
Section 19. DATA FIELD DESCRIPTIONS
for a more detailed descriptionof Event Logging.