~~g OptiOnS Defined
The following will help you understand the programming of OUTPUT
DEVICES when using *8O and *81 modes. The options used to start and
stopthesedevicesare describedbelow,followedby the actual screenprompts
and availableentries.
The letter(s)in parenthesesafter each function describedbelow, such as (A)
tier ACTION, are those that appear in the various summary displays of
programmeddata during programming.
ACTION (A) The “ACTION”of the deviceis how the devicewill respond
when it is activated by the “START programming. You
may want the deviceto activate momentarily, to pulse on
and off continuously, or to remain activated until some
other event occurs to stop it. There are four different
choicesof actions:
. ACTIVATE for 2 SECONDS and then reset.
c ACTIVATE and REMAIN ACTIVATED until stoppedby
someother event.
. PULSE ON and OFF until stoppedby someother event.
Q NOT USED when the deviceis not used.
START (S27’) The “START” programming determines when and under
what conditionsthe devicewill be activated. The following
START optionsare available:
A) 1. EVENT (EV) is the condition (Alarm, Fault, Trouble) that
must occurto a zone or group of zones(zone list) in order to
activate the device. These conditions apply
only when a
zone list is used. The different choicesfor “EVENT” are
listed below and in the “Programming Output Relays &
PowerlineCarrier devices”sectionthat follows.
Q ALARM
Relay action begins upon any alarm in
an assignedzone in the zonelist.
. FAULT
Relay actionbegins upon any opening or
short in an assigned zone in the zone
list.
TROUBLE
Relay action begins upon any trouble
conditionin an assignedzonein the zone
list.
. NOT USED Relay action is not dependent upon one
of the aboveevents.
2. ZONE LIST (ZL) is a group of zones to which the
“EVENT” applies in order to activate a particular device.
Note that there are a total of 3 zone lists that can be
programmed in field *81 mode; when the selectedEVENT
(Alarm, Fault or Trouble) occurs in any zone in the
selected“Start” ZONE LIST (1, 2, or 3), activation of the
selecteddevicewill START.
B) 1. ZONE TYPWSYSTEM OPERATION (ZT). If a System
Operation, such as
“DISARMING” or “ANY FIRE
AIARM,” is to activate the device,the appropriate choice
would also be entered under the “ZONE TYPE” option.
“ZONE TYPE” is used independently of the
“EVENWZONE LIST” combination.
If a specific“ZONE TYPE”
is chosen, any zone of that re-
sponsetype going into alarm, trouble, or fault will causethe
device to activate as selectedin “ACTION.” If the same
“ZONE TYPE” is also chosenfor the STOP programming,
any zone of that type that restores will de-activate the
device.