Vista de pagina 37
II
TRANSMIT NOW
II
If “yes” is selected’in response to the “Learn
MN?” prompt, this display will appear.
Fault and restore the transmitter to be learned.
A simzlebee~ will be heard at the kevoad. Wait
68 s~conds.’~aultand restorethe tr=mitter a
secondtime. ‘IWObeepswill be heard, indicating
acceptanceinto the system.
Note If a long beep occurs,it means that the
particular transmitter input has
previously been registered in the
system.
Mark the zone number on the transmitter. If the
transmitter is a multi-button @pe, each of the
buttons used must assignedto a different zone,
and eachof the buttons must be learned.
Typicalsummary
display
m
AccsptedInput(Loop)Number
II
Program Alpha?
o
=Nol= Yes O
I
II
Enter Zn Num.
(00 = Quit)
21
I
After a transmitter has been learned, a
summary of the programmed values for the
selectedzone will be displayed.
If all is okay, press [*].
Alpha descriptorsfor the zones can be done now
(enter 1) or maybe done at a later time using
*82 interactive mode (enter O). We recommend
that the entry of Alpha descriptors be done
using *82 mode.
Refer to
Section 15. ALPHA DESCRIPTION
PROGRAMM~G
for specificprocedure.
If you entered ‘O* (no) in response to the
Program
Alpha ? prompt, the system will
display a prompt for entry of the number for the
next wirelessexpansionzone to be programmed.
Proceedwith the progr
smming of the next zone,
as indicated previously.
5. Exit the programming
g modeby keying $H19.
6. Use the transmitter Sniffer mode to test that all transmitters have all
been programmedproperly, as indicated next.