Vista Ademco -10SE Guía para resolver problemas Pagina 84

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 83
Type06
24hour Silent Alarm
‘Ijpe 07
24hour Audible Alarm
&pe 08
24-hour
Auxiliary Alarm
Type 09
Supervised Fire
(With Verification on
Zone 1)
‘&pe 10
Interior w/Delay
‘&pe 20
Arm-stay
‘&pe 21
Arm-Away
‘&pe 22
Disarm
Type 23
No Alarm
Response
Type24
Silent Burglary
This zone type sends a report to the Central Station but provides no keypad
display or sounding. This zone @e is usually assignedto a zone containing
an Emergency button.
This zone type sends a report to the Central Station, and provides an alarm
sound at the keypad, and an audible ezternal alarm. This zonetype is usually
assigned to a zonethat has an Emergencybutton.
This zone type sendsa report to Central Station and providesan alarm sound
at the keypad. (No bell output is provided). This zone type is usually
assignedto a zonecontaining a button for use in personalemergencies,or to a
zone containingmonitoring devicessuchas water or temperature sensors,etc.
This zone type provides a fire alarm on short circuit and a trouble condition
on open circuit. The bell output will pulse when this zone type is alarmed.
This zone type is always active and cannotbe bypassed.This zone @pe can
be assigned to a control panel basic wired zone, any zone in a wired
zone expansion module, or wireless zones. When used with zone 1 on
the panel, 2-wire smoke detectors can be used. For an explanation of the
“verification” function, refer to the “Operation” paragraph in a previous
sectiontitled 2-Wire Smoke Detector Installation.
Alote:
Only hardwired zone 1 can be programmed as a firs zone in UL
in@aUations. However, any wireless wne can be used as a fire
zonQ.
This
zone type gives entry delay #1 (using the programmed en~ time), if
tripped when the panel is armed in the Away mode. Entry delay begins
whenever sensorsin this zone are violate~ regardless of whether or not an
entrylexit delay zone was tripped tist. No
entry &lay is provided if tripped
when the panel is armed in the Maximum mode.Exit delay is presentfor any
arming mode. This
zone type is b~assed when the panel is armed in
the Stay or Instant modes.
This is
a special-purposezone type usedwith 5800 serieswirelesspushbutton
units which will result in arming the system in the STAY mode when the
zone is activated. Pushbutton units send zone number as a user number to
central stationwhen
arming or disarming.
Th& is a special-purposezone @pe used with 5800 serieswirelesspushbutton
units which will result in
arming the system in the AWAY mode when the
zone is activated.Pushbutton units send zone number as a user number to
central stationwhen
arming or disarming.
This is a special-purposezone type usedwith 5800 serieswirelesspushbutton
which will result in disarmin
g the systemwhen the zone is activated.
This zone type can be used on a zone when an output relay actionis desired,
but with no accompanyingalarm (e.g.,lobby door access).
This zone type provides an instant alarm, with NO audible indication at any
keypad or external sounder, if the zone is faulted when the system is armed
in the AWAY, STAY, INSTANT, or MAXIMUM modes. This zone type is
usually assigned to all sensors or contactson exterior doors and windows
where audible notification is NOT desired. A report is sent
to the Central
Station.
NOTE:
All of the zone types described are available for the wireless portion of the system, if used.
Vista de pagina 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 119 120

Comentarios a estos manuales

Sin comentarios