TO PROGRAM
SYSTEMSTATUS
AND RESTORE
REPORTCODES
(*59-*76,&*89)
The following is a setof guidelines to be used for programming report codes.
The actual digits that you enter depend upon the particular installation, and
should be in agreementwith you and the cenlmd station officereceiving the
signals. Use theseguidelinesto program this entire section.
With a 3+1 or 4+1 Standard Forma* Enter a codein the first box 1–9, A,
B, C, D, E, or F. Enter “#+10” for A (this reports a “O” on some receivers),
“#+11”for B, “#+12”for C, “#+13” for D, “#+14”for E, “#+15”for F.
An entry of “O” in the firstbox will disablea report.
An entry of “O”in the secondbox will result in automatic advance to the
next field when programming.
With an Expanded or 4+2 Forrnati Enter codesin
both boxes(lst and 2nd
digits) for 1–9, or A–F, as describedabove.
An entry of “O’ in the
first boxwill disablea report.
An entry of “O in the
second box will eliminate the expandedmessagefor
that report.
With Ademco Contact Ill Reporting Enter a digit in the first box to
enable the zone to report. Use a di&erent digit for each zone until you have
used up available digits.
If the number of zones exceedsthe number of
availabledigits, beginwith digit 1 again. This is an “enabling”codeonly and
is not the actual codesent to the central station office.Entries in the second
boxeswill be ignored. For systemstatus (non-alarm) codes,enter a “1” in the
fist box for all the systemconditionsyou want to sendto the central station.
Au enlny of “Oin the
first box will disablethe report.
Press *59 EXIT ERROR REPORT CODE
n
fieSS *6O
fieSS *61
-S *62
Press *63
Press w
Press *65
u
If “O”is entered in this field, no speckd messagewill be sent,
only the regular alarm and alarm restorecodefor the zone. If a
non-zero codeis entered, this messagewill be sent if an ah-m
occurswithin 2 minutes after the end of the Exit time.
Refer to
Section 19. DATA FIELD DESCRIPTIONS for a
detaileddestiption of this option.
Field *59 entry note: The 2nd digit is automatically sent as
the 2nd digit of the zone alarm report codeprogrammed in * 56,
if expandedor 4+2 reporting is selected.
TROUBLE REPORT CODE
I-l_J
Thiswill
be sent if a zone goesinto trouble.
BYPASS REPORT CODE
D
Thiswill
be sent when a zoneis manually bypassed.
AC LOSS REPORT CODE
u
Reportawith Partition 1 Subscriber No. Timing of this report is
random with up to a 4-hour delay. If AC restores before the
report goesout, there is no AC restorereport.
LOW BAT REPORT CODE
IJ_J
This will be sent when a low battery condition exists in the
system’sstandby battery. Reports with Partition 1 Subscriber
No.
TEST REPORT CODE
LLl
This
is sentperiodicallyto testthat the communicatorand phone
lines are operational (Ilequency of report is selected in field
*51). Reportswith Partition 1 SubscriberNo.
OPEN REPORT CODE
Part’n lo Part’n 2 ❑
This is sentupon dis
arming of the system. 2nd digit= User No.,
if expandedor 4+2 reporting is selected.
-60-