Output Relays and Powerline Carrisr Devices
1. With at least one 2-line Alpha keypad (5137AD or 6139) connectedto the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously connectedthe AC hnsformer to the
controlpanel, you need only plug in the transformer (to 120VAC outlet)to
powerup the system.
2. Enter the programming mode by keying the following on the Alpha
keypad
Installer code (41 12) +8+ O+ O.
3. Press *7. POWERLINE
CARRIER DEVtCE HOUSE ID.
u
Enter House ID 1-15 for Powerline Carrier devices,asfollows:
0=~l=B,2=C,3 =D,4=E,5=F,6 =G,7=H,8=I,9 =J,#+10=~
#+ll=L, #+12= M,#+13=N, #+ 14=0, #+15=P.
Default is O.
The House ID must match the House ID set on the powerline carrier
devices.The unit ID for these devicesis 1-8 dependingon which deviceis
being programmed. For example, device #1 must be set to unit ID 01,
device#2 to unit ID 02, etc.
4. Press *80. Note that this is an interactiveprogr
amming mode. It is
used to program all output devices used in the system (4229 or 4204
Relay modules, or Powerline Carrier devices).Refer to the Programming
Form worksheetfor *O InteractiveMode.
OutputDeviceDisplayss
II
Enter Device No.
(00 = Quit) 01
II
I
02 AEVZLZT P
S1-roooool
I
II
02 Start Event
Not Used
o
I
m
I
02 Stare Zn Typ
Not Used 00
I
Upon pressing *80, this screenwill appear. Enter the Device Number 01 or
02 for a 4229, or 01, 02, 03, or 04 for a 4204, or 01-08 for Powerline Cfier
devices(or 00 to end these enties). press the [*I key to continue.
The [*] key is used to acceptan entry and advanceto the next prompt. The
[#] key is used to revert back to the last question to checkor change an
entry. Ress [*] to goforward again.
This screendisplays a summary of the current Device START programming
(for this example,device02 has been selected).
Press the [*] key to continue.
This screendisplays a summary of the current DeviceSTOP programming.
Pressthe [*Jkey to continue.
Enter the desireddeviceaction as listed below.Pressthe [*] key to continue.
O= No response
2 = CIoseand Stay Closed
1 = Closefor 2 seconds 3 = Continuous pulse on & off (1secON, 1secOFF)
Enter the eventto START the relay
O= Not US4 2 = Fault; 1 = Alarm; 3 = ‘llouble
A zone list must be used in conjunctionwith an event. If a zone type/system
operationis to be used instead of an event,enterO.
Ress the [*] key to continue.
If a zone list will be used to START the relay action, enter the zone list
number (to be programmed in field *81): 1, 2, or 3. If not used, enter O.Ress
the [*I key to continue.
Jf a zone type or system operation will be used to START the deviceaction,
enter the appropriatetwo-digit code(seetablethat follows). If not, enter00.
Press the [*I key to continue.
47-