Vista de pagina 61
,[07 ResponseTimel[l
Typicalsummarydisplay
1,
II
ZnZTPRCln RT
0777 1 3CHW1
II
Enter the desired response time for zone 7.
The recommended entry for keyswitch
operationis “1” (the factorydefault).
Selectionsavailableare: “O”(10 msec),“1” (350
msec),or “2” (700 msec).
Enter the desirednumbers and then press [*I
to continue.
A summary display will appear, showing the
data for zone 7 that wasjust programmed.
If it is programmed satisfactorily,press [*] to
continue.
~~f~;forzone7. .incethis}sa
The next request is to enter an Alpha
= Yes O keysmtch zone, no descriptor M requwed.
EEEL=--
If “O”(no) was entered above,the system will
display a prompt for entry of the number for
Press [0] [0] plus [*] to exit *56 mode.
Exit the programming mode by keying *99.
After keyswitch operation is verified (see
beIow), unplug the AC transformer and
proceedto the next section.
KeysWitch Operation
To arm AWAY, turnkey and releasewithin a l/2 second. To arm STAY,
turn
and hold key for longer than 2 seconds.To disarm, turn key and
immediatelyrelease.
LED indications are defined as follows:
GREEN
RED MEANING
I
OFF OFF DISARMED & NOT READY
ON
OFF
DISARMED & READY
OFF
ON STEADY
ARMED AWAY
OFF SLOW FLASH ARMED STAY
OFF RAPID FLASH
AIA.R.MMEMORY
-62-
Vista de pagina 61