check-out Procedure For Wmd EX@iWSiOQ Zcmes -
After you have completedinstallation of all devices,all expansion zones in
euch ptition of the securitysystemshouldbe checkedas follows:
1.
2.
3.
4.
5.
Make certain that all devices and sensors connected to the wired
expansion zones are not in a faulted state. Doors and windows with
contactsshould be closed,PIRs should be covered (use a cloth to mask
them temporarily if necessary).
With all zones intact (including hard-wired zones), the Alpha keypad
connectedto the systemshould display:
~~
If the followingis displayed,
m
press the [*] key to display the faulted zone(s). Restore any faulted
zone(s)as necessary(also make sure that you have connecteda 1000 ohm
EOL resistor acrossthe terminals of unused expansion zones on the 4219
or 4229 module).
When the READY TO ARM messageis displayed, you can proceedto the
next step.
Fault and restore every contact or sensor in each expansion zone
individually to ensurethat it is being monitored by the system. Each time
a zoneis faulted, the keypad shoulddisplay the number of the faulted zone
(as programmed by you just previously in *56 mode). When each zone is
restore~ the READY TO ARM messageshould appear again.
If some wired expansion zones have been assigned to partition 1 and
others to partition 2, you will need to observe the keypad in the
appropriate partition as eachzonein that partition is faulted and restored.
When you get the proper displays on the keypad(s), the tied expansion
zonesin the systemare functioningproperly.
Unplug the AC transformer.
+1-