*27
POWERIJNE CARRIER DEVICE (X-1O) HOUSE ID
Powerline Carrier devicesrequire a House ID. This field identifies
this houseID to the control.
If PowerlineCarrier devicesare used, they are selectedin field * 80.
House ID is enteredin followingmanner:
0= A,1=B,2=C, 3= D,4=E,5=F, 6= G,7=H,8=I,9=J,
#+10= ~#+ll=L, #+12= M,#+ 13= N,#+14=0, #+15=P.
Default is O.
*28
VOICE MODULE PHONE CODE
m
The use of a 4285 Voice Module (can be used in Partition 1 only)
requiresa 2-digit code.
Enter a 2-digit phone accesscodeas follows: For first digit, enter
any any digit from 1 to 9; for second digit, enter # +11 for “*”, or
# +12 for “#”.
ExampZe: If desiredaccesscodeis 7*, 7 is the first entry, and # + 11
(for *) is the secondentry.
*9 OUTPUT TO LONG RANGE RADIO (No. 7720 PLUW7820)
If output to LR.R is selectedhere, all messagesthat are programmed
to go to the primary telephoneline receiver wiIl also be sent to the
7720 PLUS or 7820radio. Thesemessageswill always be in Contact
ID format (not affected by entry in field *48). The data line is
supervised as well as certain functions in the radio. If
communication is lost or a trouble develops, a message will be
attempted to be sent via both radio and telephone to the central
station.
Note: Normal trouble restorereport (*71) is sent on restore of the
condition.
Entry is first digit of Trouble Dialer Repo~ enter Trouble code1-9,
B (# +11), C (# +12), D (# +13), E (# +14), or F (# +15). The 2nd digit
of Trouble Dizder Report is automatically the 2nd digit fkom field
*60. For UL installations, Long Range Radio must be
disabled (enter “O”).
Note: The Radio should be programmed for deviceaddress 3 on the
keypadlines.
*3O
KEYSWITCH ENABLE
•1
This field must be enabled (enter 1) if using a keyswitch. The
keyswitchmust be connectedto zone 7, which can then not be used
for any other purpose.
Default is O (no keyswitch).
If keyswitchis enabled,in menu mode *56 the Zone me (ZT) for
‘zone 7 will show “77”, and the zone will not be accessiblefor
progr
amming.
If the 4146 kewnvitch is used
with onlv Red and Green LEDs
connected(no iock switchand tamper
&tch) to simply provide
an armingkeady
status indicator panel, zone 7 can then be used
as a hard-wired protectionzone, provided you do not enable
this field.
ZONE SOUNDS AND
*32
SINGLE ALARM SOUNDING PER ZONE
(per armed period)
(*=:
This field limits alarm soundingto once per arming period for a given
zone. Enter 1 for yes; default is
O (no). Enter 60- for UL
installations.
*33
FIRE SOUNDER TIMEOUT
•1
This field determineswhether the external sounder will shut off after
time allotted, or continue until manually turned off. Enter O for
soundertimeout, or
1 for no timeout. Default is O.
Enter ‘@B for UL installations.