Vista Ademco -10SE Guía para resolver problemas Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
Using The Tmnsmitter Sniffer Mode
1. Enter Installer code (4112)+ # + 3. This initiates a procedure that will
providea checkthat all transmitters have beenproperly programmed.
2. The keypad wilI display all zone numbers of wireless units programmed
into the system.Fault eachtianemitter in tumq causingeach oneto send a
signal, rather than let each transmitter send an automatic
supervisory signal. An automaticsupervisorysignal that is receivedin
this modewill bemisinterpreted as a low battery signal.*
As the system receivesa signal fkom each of the transmitters, the zone
number of that transmitter will disappear from the display. The
transmittersmay be checkedupon installation, or in an installed system.
Note: A transmitter not “learned”will not turn off its zone number.
3. When all transmitters have been checked, exit the sniffer mode
immediatelyby keying Installer code (4112)+ OFF.
* If oneormorelowbatterymessagesdoappearafterexitingthesniffermode,doone
ofthefd.lowing
A Faulteachzonethat is showinga lowbattery,then entera disarmsequence
(Code+ OFF) toclearthelowbatterydisplay,or..
B. Enterandexitthe programmingmode.Thiswill clearany lowbatterysignals
&ommemory.
~~p
To Either T
ermaneatly Remove A Zone From The System.
1. Enter the programming mode and press[*1[51[61.
2. Enter the zonenumber and press[*I. A summary display will appear.
3. Ress [*] again.
m ‘ess[*]timntiue
4. The “Zone Type” prompt will appear. Enter
[01[01.This setsthe zonetype to “Not Used”.
- “le’thezOne”
5. The next prompt will ask whether you want
‘Yes” vnll permanently remove the zonefkom
the system,while a “No”will disableit but re-
tain all data exceptthe original zone @pe. You can then go back to this zone
later and put backan activeZoneType to re-enableit.
A serial number that has been learned for a 5800 system will not be
deleted if the zone is temporarily disabled by answering ‘Non to the
prompt above.
If only the physicaltransmitter is to be removed or changed (i.e., its sefia.1
number deleted,as when replacing a unit that has a non-removable battery),
it can be done in *56 Mode, but we recommend using the *83 mode (in a
later sectionof this manual).
Deleting a Transmdt
erSerial Nmnber Froma~in x56 Mode
Abbreviated
1.
Procedure:
2.
3.
4.
5.
6.
~o~~ programming mode, press [*1[5][61to enter Zone Programming
Then.enter the zone number, and press [*I mpeate~y ~fl the cursor iS
under the %mmed RF Input (L)” position. ~S is the spefic mPut
(loop)or button on the transmitter that has beenlearned for that zone.
En~ a [O]at this point, then press[*I.
A prompt “Delete S/N?” will appear.
Enter ‘Yes”to deletethe existingserial number from the system.
Note that the other programmed values for that zone will not be deleted.
This will allowyou to r~instate a new transmi
tter in its place.
A displayfor the next zone number will appear.To exit, enter “00 *“
Press*9 to exitthe programming mode.
-39-
Vista de pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 119 120

Comentarios a estos manuales

Sin comentarios