This sectionprovides instructions for the connectionof an optional remote 4146 keyswitch
for remote arming and disarmin
g of the system, and the progr
amming necessarywhen a
keyswitch is used. Also included is a description of how the keyswitch operates in the
system.
Installing the Keyswitch
The remote 4146 keyswitch(with red and green LEDs to indicate status) is
connectedto zone 7.
Note that you canuse a keyswitchin one partition only.
Remote Keyewitch Connection
1. Connectthe 4146 keyswitchs normally open momentary switchto zone 7
terminals (18 and 19). Removethe 2000 ohm EOL resistor if connected
acrosszone 7 terminals.
2. Connect the Red and Green LEDs to pins 7, 8, and 9 on the 9-pin
connector,using a 4142TR cableas shownin Figures 19 (A) and(B).
3. Connecta 2000 ohmEOL resistoracrossthe momentary switch
4. You can wire an optional closed-circuit tamper switch (model 112) in
serieswith the zone.If the switchplateis then removed from the wall, the
tamper will open, disabling keyswitch operation until the system is next
disarmedfkomthe keypad.
If the tumper (or zorw 7 loop wires) is opened when the system is armed, an
cdanmwill occur.
-s9-