TO PROGRAM
SYSTEM STATUS
AND RESTORE
REPORT CODES
(*59 -76, & *89)
The following is a set of guidelines to be used for progr
amming report codes.
The actual digits that you enter depend upon the particular installation, and
should be in agreementwith you and the central station officereceiving the
signals. Use theseguidelinesto program this entire section.
With a 3+1 or 4+1 Standard Forraati Enter a codein the
first box 1–9, ~
B, C, D, E, or F. Enter “#+10 for A (this reports a “O” on some receivers),
“#+11”for B, “#+12”for C, “#+13 for D, “#+14”for E, “#+15” for F.
An entqy of “O in the
first boxwiIl disablea report.
An entry of “O”in the secondbox will result in automatic advance to the
next field when programming.
With an Expanded or 4+2 Formati Enter codesin
both boxes(lst and 2nd
digits) for 1–9, or A-F, as describedabove.
An entry of “O in the
first boxwill disablea report.
An entry of “O”in the
second box will eliminate the expanded messagefor
that report.
With Ademco Contact ID Reporting: Enter a digit in the first box to
enable the zone to report. Use a different digit for each zone until you have
used up available digits. If the number of zones exceedsthe number of
available digits, beginwith digit 1 again. This is an “enabling”codeonly and
is not the actual codesent to the cential station office.Entries in the second
boxeswill be ignored. For systemstatus(non-alarm) codes,enter a “1” in the
first box for all the systemconditionsyou want to send to the centml station.
An entry of “O”inthe
first box will disablethe report.
SYSTEM STATUS *59 _ -OR REpORT CODE (See ~x above.)
REPORT CODES
(*56456)
If the systemis armed and an Entry/Exit or Interior zone is still open
after the exit delay time has expired, an alarm will sound at the
keypad and external sounder (keypad also displays “Exit Alarm”). If
the system is disarmed before the end of the entry delay that
immediately follows, the alarm sounding will stop and no message
will be sent to the central station. The keypad will display CA
(fixed-wordkeypads)or CANCELLED MAR.M (Alpha keypads).
If the system is not disarmed before the end of the entry delay
mentioned above,and an Entry/Exit or Interior zone is stiIl open, an
‘exit alarmm message will be sent to the central station if an
Exit Error Report code is selected in this field. The keypad will
display EA (fixed-word keypads) or EXIT ALARM (Alpha keypads),
and the alarm sounding will continueuntil the systemis disarmed (or
timeout occurs).
An “Exit Alarm” conditionwill alsoresult if a fault occursin an exit or
intenor zonewithin 2 minutes following the end of the exit delay, and
an “exitalarm” messagewill be sentto the central station.
If ContactID format has been programmed, the messagewill contain
the zonenumber and error code374 (Troubl~Exit Error) to define the
alarm as an Exit Error (rather than E/E or Interior). If 4+2 format is
used, the digit enteredin this field will be sent followedby the second
digit ofthe programmed alarm codefor that zone. If 3+1 or 4+1 format
is used, only the digit enteredin this field will be sent. This message
will go to the Primary Phone No. Under any of these conditions, no
Restoremessagewill be sent.
If “O”is enteredin this field, no specialmessagewill be sent, only the
regular alarm and alarm restorecodefor the zone.
*60
TROUBLE REPORT CODE (Seebox above)
m
*61
BYPASS REPORT CODE (Seebox above)
D
-92-