–59–
10 INPUT DEV: LP#
RF TRANS. RF: 1
Loop number (LP#): Enter the loop number (1-4) for the zone of the
transmitter being enrolled. The default is loop "1." To accept this, press
[
*
]. If a different loop number is being used on this transmitter, enter the
desired loop number and press [
*
] to continue (see the transmitter's
Installation Instructions for specific loop designations). The loop number
must be entered here, whether using Zone Programming or
Sequential Mode to "enroll" transmitters.
10 LEARN S/N?
0 = NO, 1 = YES 0
If the transmitter’s serial number has not been previously “enrolled,” you
may enter the enroll mode now by either entering "1" (YES)
or
by
pressing the upper left-hand button of the program tool. If using the
program tool, move to the physical location of the transmitter to be
enrolled before pressing the button. A single short beep will verify that
the button has been pressed. The system will respond to the first serial
number transmitted after the [
*
] key on the keypad or the button of the
program tool is pressed. Enter "0" (NO) if you wish to enroll the
transmitter later, using the “*83 sequential” mode described in the
SEQUENTIAL MODE
section later in this manual.
If "0" is entered, skip to the summary screen prompt.
10 INPUT S/N: L
A X X X–X X X X
This prompt is displayed if "1" (YES) is entered in response to the "Learn
S/N?" prompt. The serial number may be enrolled by one of two
methods:
a) Enter the 7-digit serial number printed on the transmitter using an
alpha keypad
or
b) Activate the transmitter by faulting
or
restoring the input you wish to
use for that zone (e.g., press a button, open or close a door, etc.).
10 INPUT S/N: L
A002-4064 1
The system will enroll the serial number of the first transmitter heard, add
the loop number entered to this serial number, display the serial and loop
numbers, and cause the keypad to beep twice.
If the serial and loop number combination is already present in the system,
a single long beep will be heard from the keypad. If this happens, the
system will not display the serial number, but will wait for a transmission
from another transmitter or transmitter loop input.
The system will then enter an optional confirmation mode so that the
operation of the actual programmed input can be confirmed. Activate the
loop input or button that corresponds to this zone. We recommend that
you confirm the programming of every transmitter before
proceeding to the next zone.
10 CONFIRMED
A022-4064 1
When the system sees activity on the appropriate input, it will beep three
times and display the confirmation message.
At any time during this step, you may press the [
*
] key on the keypad or the
upper left-hand button of the program tool if you are satisfied with the serial
and loop number combination that has been enrolled, regardless of whether
or not the enrolled input has been "confirmed."
If the incorrect transmitter has been enrolled, press the [#] key on the keypad
or the upper right-hand button of the program tool to delete the serial number
and return to the "LEARN S/N" prompt. A single long beep will be heard from
the keypad to verify pressing of the upper right-hand button. Then, press "1"
(YES) or press the upper left-hand button of the program tool (a single short
beep will verify the system is ready for enrolling) and re-activate the proper
transmitter or transmitter loop input.