49 SPLIT/DUAL REPORTING 0
Use options 0 - 5 when reporting to standard telephone receivers
TO PRIMARY TO SECONDARY
0 = All reports none, unless primary fails, then all
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All reports All
Use options 6 - 9 when reporting to a pager is desired
TO PRIMARY TO PAGING No.
6 = All reports except Open/Close Alarms, Open/Close, Troubles
7 = All reports Alarms, Troubles
8 = All reports Alarms, Open/Close, Troubles
9 = All reports except Open/Close Alarms, Open/Close for users 5-25
,
Troubles
Can only be used is primary reporting format is Ademco Contact ID. See
explanation of pager report format below.
Will report users 5-16, and, if using wireless button-type devices, will report
the zone number of the arm or disarm button (10-25). Open/Close for users 1-
4 are not reported.
Pager Report Format
Options 6-9 send reports to the primary phone number and send reports
to a pager, which has its phone number entered as the secondary phone
number in field *42.
The pager report is a 10-digit code in the following format:
SSSS–EEE–NNN
where: SSSS = 4-digit subscriber number (field *43; first digit cannot be
0)
EEE = 3-digit event code as follows:
911 = alarm (NNN = zone number)
001 = Open, system disarmed (NNN = user no.)
002 = Close, system armed (NNN = user no.)
811 = Trouble (NNN = zone no.)
NNN = 3-digit user number or zone number as described in
EEE
Refer to the User Manual for examples of pager displays.
*
50 15-SECOND DIALER DELAY (BURGLARY) 0
0 = no dialer delay
1 = provide 15-second delay of burglary alarm report (except zone type
24) to the central station, which allows time for the subscriber to avoid a
false alarm transmission. This delay does not apply to zone type 24
alarms, which are always sent as soon as they occur.
UL installations: must be 0 (no delay)
*
51 PERIODIC TEST REPORT 0
0 = no test report
1 = once every 24 hours
2 = weekly
3 = once every 30 days
Test Report Code entered in field
*
64 is sent. Reports with Partition 1
Subscriber No.