SYSTEM STATUS
REPORT CODES
(
*
59–
*
68)
*
59 EXIT ERROR REPORT CODE (See box on previous page) 0
If the system is armed and an Entry/Exit or Interior zone is still open after
the exit delay time has expired, an alarm will sound at the keypad and
external sounder (keypad also displays “Exit Alarm”). If the system is
disarmed before the end of the entry delay that immediately follows, the
alarm sounding will stop and no message will be sent to the central
station. The keypad will display CA (fixed-word keypads) or CANCELED
ALARM (Alpha keypads).
If the system is not disarmed before the end of the entry delay mentioned
above, and an Entry/Exit or Interior zone is still open, an “exit alarm”
message will be sent to the central station if an Exit Error Report
code is selected in this field. The keypad will display EA (fixed-word
keypads) or EXIT ALARM (Alpha keypads), and the alarm sounding will
continue until the system is disarmed (or timeout occurs).
An “Exit Alarm “ condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay, and an
“exit alarm” message will be sent to the central station.
If Contact ID format has been programmed, the message will contain the
zone number and error code 374 (Trouble–Exit Error) to define the alarm
as an Exit Error (rather than E/E or Interior). If 4+2 format is used, the digit
entered in this field will be sent followed by the second digit of the
programmed alarm code for that zone. If 3+1 or 4+1 format is used, only
the digit entered in this field will be sent. This message will go to the
Primary Phone No. Under any of these conditions, no Restore message
will be sent.
If “0” is entered in this field, no special message will be sent, only the
regular alarm and alarm restore code for the zone.
*
60 TROUBLE REPORT CODE (See box above) 0 | 0
This will be sent if a zone goes into trouble.
*
61 BYPASS REPORT CODE (See box above) 0 | 0
This will be sent when a zone is manually bypassed.
*
62 AC LOSS REPORT CODE 0 | 0
See box on previous page. Reports with Partition 1 Subscriber No.
Timing of this report is random with up to a 4-hour delay. If AC restores
before the report goes out, there is no AC restore report.
*
63 LOW BAT REPORT CODE 0 | 0
This will be sent when a low battery condition exists in the system’s
standby battery. See box. Reports with Partition 1 Subscriber No.
*
64 TEST REPORT CODE 0 | 0
This is sent periodically to test that the communicator and phone lines
are operational (frequency of report is selected in field *51). See box.
Reports with Partition 1 Subscriber No.
*
65 OPEN REPORT CODE 0
This is sent upon disarming of the system. See box. 2nd digit = user
number, if expanded or 4+2 reporting is selected.
*
66 ARM AWAY/STAY REPORT CODE 0 | 0
This option allows for independent programming of AWAY and STAY
reports for each partition. 2nd digit of report is user number if expanded
or 4+2 reporting is selected.
NOTE: OPEN reports are not sent in if the associated closing report is
not enabled.