Type 06
24-hour Silent Alarm
This zone type sends a report to the Central Station but provides no keypad
display or sounding. This zone type is usually assigned to a zone containing an
Emergency button.
Type 07
24-hour Audible Alarm
This zone type sends a report to the Central Station, and provides an alarm
sound at the keypad, and an audible external alarm. This zone type is usually
assigned to a zone that has an Emergency button.
Type 08
24-hour
Auxiliary Alarm
This zone type sends a report to Central Station and provides an alarm sound at
the keypad. (No bell output is provided). This zone type is usually assigned to a
zone containing a button for use in personal emergencies, or to a zone containing
monitoring devices such as water or temperature sensors, etc.
Type 09
Supervised Fire
(With Verification on Zone
1)
This zone type provides a fire alarm on short circuit and a trouble condition on
open circuit. The bell output will pulse when this zone type is alarmed. This zone
type is always active and cannot be bypassed. This zone type can be assigned
to a control panel basic wired zone, any zone in a wired zone expansion
module, or wireless zones. When used with zone 1 on the panel, 2-wire smoke
detectors can be used. For an explanation of the “verification” function, refer to
the “Operation” paragraph in a previous section titled 2-Wire Smoke Detector
Installation.
Note: Only hardwired zone 1 can be programmed as a fire zone in UL
installations. However, any wireless zone can be used as a fire
zone.
Type 10
Interior w/Delay
This zone type gives entry delay #1 (using the programmed entry time), if tripped
when the panel is armed in the Away mode. Entry delay begins whenever
sensors in this zone are violated, regardless of whether or not an entry/exit delay
zone was tripped first.
No entry delay
is provided if tripped when the panel is
armed in the Maximum mode.
Exit
delay is present for
any
arming mode. This
zone type is bypassed when the panel is armed in the Stay or Instant
modes.
Type 20
Arm–Stay
This is a special-purpose zone type used with 5800 series wireless pushbutton
units which will result in arming the system in the STAY mode when the zone is
activated. Pushbutton units send zone number as a user number to central
station when arming or disarming.
Type 21
Arm–Away
This is a special-purpose zone type used with 5800 series wireless pushbutton
units which will result in arming the system in the AWAY mode when the zone is
activated. Pushbutton units send zone number as a user number to central
station when arming or disarming.
Type 22
Disarm
This is a special-purpose zone type used with 5800 series wireless pushbutton
which will result in disarming the system when the zone is activated.
Type 23
No Alarm Response
This zone type can be used on a zone when an output relay action is desired, but
with no accompanying alarm (e.g., lobby door access).
Type 24
Silent Burglary
This zone type provides an instant alarm, with NO audible indication at any
keypad or external sounder, if the zone is faulted when the system is armed in
the AWAY, STAY, INSTANT, or MAXIMUM modes. This zone type is usually
assigned to all sensors or contacts on exterior doors and windows where bells
and/or sirens are NOT desired. A report is sent to the Central Station.
NOTE: All of the zone types described are available for the wireless portion of the system, if used.