–23–
Section 6. WIRELESS EXPANSION
(5800 SYSTEM)
This section provides instructions for installing 5800 series wireless receivers
and transmitters.
General Information
In addition to its basic wired zones, the control supports up to 24 wireless zones
using an appropriate 5881 (5882 in Canada) type RF receiver. The actual
number of zones supported depends on whether you are using a wired zone
expander module.
For example:
If you are using only four of the wired expansion loops, a 5881H
(5882H in Canada) RF Receiver could add 20 RF zones to the system, using any
unused zone numbers 10–31, for a combined total of 24 wired and wireless
expansion zones.
The receiver can detect signals from wireless transmitters within a nominal range
of 200 feet.
RF Receiver No. of Zones
5881L/5882L up to 8
5881M/5882M up to 16
5881H/5882H up to 24
Receiver Supervision
The receiver is supervised, and a trouble report will be generated. CHECK and
zone 09 will also be displayed.
a) If communication between the panel and the receiver is interrupted.
or
b) If no valid RF signals from at least one supervised wireless transmitter are
received within 12 hours.
House Identification
If you are using a 5804BD, 5827 or 5827BD Wireless Keypad with the system,
you must program a House ID Code (01–31) in field
*
24 to establish proper
communication, and the keypad must be set to the same ID.
House ID 00 disables all wireless keypads.
Installing the 5881/5882 Receiver
RF System Installation Advisories
Disregard the following advisories if the receiver is mounted in the control
cabinet.
1. Place the RF Receiver in a high, centrally located area for best reception.
2. Do not locate the receiver or transmitters on or near metal objects. This will
decrease range and/or block transmissions.
3. Do not locate the receiver in an area of high RF interference (revealed by
frequent or prolonged lighting of the LED in the receiver. . .random flicker is
OK).
4. The RF receiver must be at least 10 feet from any remote keypads to avoid
interference from the microprocessors in those units.
Comentarios a estos manuales