Pagina 1 - Installation Instructions

~STA-10SECURITY SYSTEMInstallation Instructions.- -‘, .s..!.,, .>’-.. .N7227V29194Previous MenuAddition of new 5800 series transmitters withthis co

Pagina 2 - VISTA-10

5800 System To install the particular transmitters in a 5800 system, one of two optional methodsTransmitter Installation can be used. Option 1, whose

Pagina 3 - ●56) ...20

RELAY OUTPUTSNo. 4204The VISTA- 10 can support 4 relay outputs via the use of a 4204Output Relay ModuleOutput Relay Module. This module provides form

Pagina 4

Mounting the CabinetInstalling the Lock(if Used)E3E3zT!secured wthout a lock by usingInstalling the Control%Clrcult Board Alone,or ([f used),with a 42

Pagina 5

Installing Control and 1.RF ReceiverClrcult Boards 2.Together,in the Same Cabinet3.IMPORTANT!Before installingthe 4.cabinet’e contents, besure to remo

Pagina 6

(See Summary of Connections Diagram on Page 47)IMPORTANT: Do not connect the battery, or plug In the AC transformer,until all other wiring connections

Pagina 7

Power-up Procedure1. Make sure that the total current to be drawn from the Alarm Output terminals(3& 4) and Auxiliary Power Output terminals (4&am

Pagina 8

General InformationInstaller options are stored in non-removable, electrically erasable, non-volatileEEROM memory. These options must be programmed fo

Pagina 9 - ●24 to establish proper

Summary ofProgrammingCommandsSpecial MessagesFUNCTIONPROCEDUREENTER PROGRAMMING MODEINITIALIZE DOWNLOAD IDANDSUBSCRIBER ACCT NUMBERFOR DOWNLOADINGSET

Pagina 10

PROGRAMMING DATA FIELDSI THE CENTERFOLD PROGRAMMiNGFORMCAN BE USED TO RECORD THE DATA FOR THIS INSTALLATION[SYSTEM SETUP *2O(“20-’27)*21●22*23*24●25*2

Pagina 11

DIALERPROGRAMMING(*40-*50]In Fields’40, *41, ●42:Enter up to the numberof digits shown.Do not fill unused spaces.Enter O-9,#+1 1 for ‘*’,#+12 for %’,#

Pagina 12 - RmAINERCLIP

CONGRATULATIONS!On Your PurchaseoftheVISTA-10The purpose of these Installation Instructions is to give you a complete overview of the system, and prov

Pagina 13 - LossMouNllNa OLIPS

*52ZONE ASSIGNMENT/*56ALARM REPORTCODES, etc.(*56)Enter Zn Num.(OO=Quit) 20Zone 20 entered~Zone TypeTZONE 3 RESPONSE TIME TO OPENO = 400ms nominal1 =

Pagina 14

Eiiiml24-hour Silent AlarmIEiiiml24-hour Audible Alarm24-hourAuxiiiary AiarmEiiEmilSupervised FireEiiiimlinterior w/DeiayEiiimilArm-StaymArm-AwayEiiii

Pagina 15 - Power-up Procedure

EEE51‘0’”[*lor[ol’~or~i:equiva,entLearning RF Input (L): Applicable to a 5800 system on/y.Where a Yes No IS asked by the console, pressing theThis req

Pagina 16

TO PROGRAM SYSTEMWith a 3+1 or 4+1 Standard Format: Enter a code in thefirst digit box: 1-9, 0, B, C,STATUS & RESTORED, E, or F. Enter “#+1O for O

Pagina 17 - PROCEDURE

OUTPUT AND*8OOUTPUT RELAYSSYSTEM SETUPApplicable only if field●25 is programmed for a 4204... otherwise skip this(“80-”92)field.REFER TO THE OUTPUT RE

Pagina 18

Ex!EaRe\aybeingprogrammed.Es_3E==7Upon entering field ●80, this screen will appear. Enter the Relay Number 01, 02,03, or 04 for a 4204 (or 00 to end t

Pagina 19

Example ofLet us light an indicator when any one of 3 specific zones areOutput Relayfaulted or when any 24 hour aux. zone is disturbed. We want toProg

Pagina 20 - Zone Type

●96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No.FOR DOWNLOADING(Nodata entry required, loads defaults)*97SET ALL PROGRAM FIELDS TO DEFAULT VALUES(N

Pagina 21 - :pre55[*1toad

IN STEPS 3-5,THE CONSOLE KEYSPERFORMTHE FOLLOWING FUNCTIONS[3][1][6][8]Advances through alphabetand actual words in alpha-betical order.Moves backward

Pagina 22 - ‘0’”[*lor[ol’~or~i:equiva,ent

ALPHA FIXED DICTIONARY(For Entering Zone Descriptors)000 (Word Space)● 001 AIR● 002 ALARM003 ALCOVE004 ALLEY005 AMBUSH● 006 AREA. 007 APARTMENT008 ART

Pagina 23

Section 1. GENERAL INFORMATION ... 5Introduction...5ZoneCharacteristics...

Pagina 24 - ●81 .When an

Report Code FormatsThe Report Codes for Alarm, System Status, and Restore forZones shown in program fields *56-*75 can be selected in field *46to repo

Pagina 25

The Ademco Contact ID Reporting format comprises a 4 digit subscribernumber, 1 digit event qualifier (“new” or “restore”), 3 digit event code, 2 digit

Pagina 26 - Zone Listselected

General InformationThe VISTA-1 O can be remotelv woarammed from an IBM comDatibie PersonalNote:Computer (PC), a Hayes Modern,”and Ademco’s V-LINK@ Sof

Pagina 27 - ToEXIT ’98

Keypad entries are ignored during the time interval stated above.A copy of the program downloaded may be produced from the IBM PCcompatible computer,

Pagina 28

Arming FunctionsThe following is a brief list of system commands. For detailed informationconcerning system functions, refer to the User’s Manual.Disa

Pagina 29 - CHARACTER (ASCII) CHART

Bxit Alarm● A display of “CANCELED ALARM” or “CA” and a zone indicationDisplayswill appear if an exit or interior zone contained a fault during closin

Pagina 30

ProcedureAfter installation is completed, the Security System should be carefully tested.1. With the System in the disarmed state, check that all zone

Pagina 31

TROUBLESHOOTING GUIDESYSTEMSYMPTOMPOSSIBLE CAUSE REMEDY1.Transmitted signal not ra-la. rnitteror 4281/5881notproperfy~w-la Checkorchangetransmitter’sb

Pagina 32

TROUBLESHOOTING GUIDE (continued)S Y S T E M (continued)SYMPTOMPOSSIBLE CAUSEREMEDY7.Intrusion alarm for no ap-7a. Protecteddcororwindowopenedwhile7a.

Pagina 33 - KEYPAD FUNCTIONS

SPECIFICATIONSVISTA- I OSECURITV CONTROL4127REMOTE CONSOLE4137AD & 5137ADREMOTE CONSOLES1. Physical: 12-1/2’’ Wx14-l/2” Hx3D (318mmx368mmx76mm)2.

Pagina 35 - TROUBLE CONDITIONS

6127REMOTE CONSOLE6128REMOTE CONSOLE6137REMOTE CONSOLE6138 &6139REMOTE CONSOLES4281L, 4281M, 4281HRF RECEIVERS(5700 System)and5881L, 5881M, 5881HR

Pagina 36

ACCESSORIES (COMPATIBLE DEVICES)AccessoriesNo. 1321/TF2 16.5VAC, 25VA Plug-In Transformer (in U.S.A.)No. 1321 CN 16.5VAC, 25VA Plug-in Transformer (in

Pagina 37 - TROUBLESHOOTING GUIDE

5827BD Wireless Bidirectional Console(used with 5800TM Transmitter Module)Can operate the system similarly to wired consoles and can indicate system s

Pagina 38 - (continued)

BINPUT(LOOP)(R#ED)(TER~NALS)Lz4(PRIMARY)2(AUX. CENTER)LEARN AS ‘RF’ LEARN AS “RF”58165817F000INPUT(LOOP)1LEARN AS “RF”5818ISET HousE CODE\ ISET Hous E

Pagina 39 - SPECIFICATIONS

OUTPUT RELAY EXAMPLES TABLERELAYACTION DESIREDSTARTSTOPACTIONAEV ZL ZT ZL ZTZones in zone list (x) close relay for 2 seconds on alarms.11x00 0 00Zones

Pagina 40

(continued) OUTPUT RELAY EXAMPLES TABLERELAYACTION DESIREDACTIONSTARTSTOPA EV ZL ZT ZL ZTClose relayat start of entry time and reset with key entry of

Pagina 41 - S@em Senso

DIP SWITCH TABLES FOR 5700 RF SYSTEM WIRELESS DEVICESNote: For a 5827 (5800 System) Wireless Keypad,House ID settings are opposite to thosefora 5727 (

Pagina 42 - (5806SHOWN)

#------}r 1,,,,:Z:J,0=, I‘9:{CJ: ;,,t::L,,::::,,{%,& -.‘.,‘i●‘.‘,‘,‘,‘...1—3-47-

Pagina 43

FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 1S STATEMENTThis equipment has been tested to FCC requirements and has been found acceptable for use. The

Pagina 44 - OUTPUT RELAY EXAMPLES TABLE

CANADIAN DEPARTMENT OF COMMUNICATIONS(DOCI STATEMENTNOTICEThe Canadian Department of Communications label identifies certified equipment. This certifi

Pagina 45

IntroductionAlarm Output AdvhmyThis system includes an alarmoutput rated at 2 amps.Throughout the manual,wherever reference ismade to Alarm OutputRati

Pagina 46 - “dn” and “dn” is “1.lp”)

WARNINGTHE LIMITATIONS OFTHIS ALARM SYSTEMWhile this System is an advanced design security system, it does not offer guaranteed protection against bur

Pagina 47 - ‘9:{CJ: ;

INDEX1321flF2, 39,411321CN, 39,4141275,394137AD, 5,394204,5,6, 11, 12,404281,5, 6,94281H, 6,8,404281 L, 6,8,404281M ,6,8,404285,5, 13, 18,27,28,29,415

Pagina 48 - ●92) must be unlimited

ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates(“Seller”)

Pagina 49 - (DOCI STATEMENT

V9STA=IO PROGRAWIM#NG FORMFIELD FUNCTIONPROGRAMMED VALUES[ ]= DsfWtt valueSYSTEM SETUP (*20-*27)●2O’21●22*23●24’25●26*27MASiER CODEQUICK ARM ENABLERF

Pagina 50 - THE LIMITATIONS OF

’52 ZONE3 RESPONSE TO OPENt❑ [0. 400 me nominal];1.10 msnomin~ (t see pre~~”~ page)●56 ZONE ASSIGNMENT/ALARM REPORT CODES (See explanationon next page

Pagina 51

IN THEZn =ZONE NUMBER~=ZONE TYPEfPRCVi OUS PA GS’i8 ZO’US AS SI@NMC#47zoneNoe.arefromolto@85,86.-sanle ampre-eedgnad.wi(hFfefdY22eetfwRF(67000r.5600),

Pagina 52 - N7227V2 9194

OUTPUT RELAYS WORKSHEET FOR FIELDS *80, and *81.Applicable only if relays are to be used.Fiii in required data and foiiow detaiied programming procedu

Pagina 53 - O PROGRAWIM#NG FORM

Zone CharacterlstlcsZones 1-6 Wired Programmable Zones. EOLR supervised,‘or more information,N.O. or N.C. sensors, 300-500 msec normai response.Seepag

Pagina 54

HARD-WIRED ZONESZones 1-6 The VISTA-10 supports 6 hard-wired zones, which are connected as zones 1-6.(Basic Control’s Zones)These zones must be EOLR s

Pagina 55 - ❑clclclclnclnnncln

WIRELESS EXPANSION-6700 & 5800 RF SYSTEMS -IVo te: In Canada, 5800 systems must use 5882 series receivers: 5882 L/588wInformation in this manual r

Pagina 56 - ❑ ❑ n ❑l

House IdentificationTransmitteridentificationRF SysteminstallationAdvisories5700 SYSTEMThe 4281 responds only to transmit-ters set to the same House I